Advantech BB-232HESP

SPHINX in Europe
UK
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Product groups > Protection Modules > Advantech BB-232HESP

Advantech BB-232HESP

RS-232 Surge Protector - 3-stage, 5-line

Advantech BB-232HESP
5530_17014.png
5530_32925.jpg
5530_32926.jpg
  • PropertiesProperties
  • DescriptionDescription
  • Further InformationFurther Information
  • PDFPDF
  • Three stages of protection on every data line:
  • - Gas discharge tube,
  • - Series resistor,
  • - Transient voltage suppressor
  • Protected signal ground connection
  • Rugged terminal block connections
  • Dedicated chassis ground lug
These three-stage surge protectors protect against lightning strikes, power surges, and other types of voltage disturbances with three stages of protection for each line: a gas discharge tube followed by a series resistor and finally a Transient Voltage Suppresser (TVS).
The surge protectors housed in a tough metal, panel mount case with a protected signal ground connection and dedicated chassis ground lug.In order to work properly, it is important to have a good connection between the #10 screws and a solid earth ground. Two terminal posts and two metal mounting brackets provide a good ground connection.
ProdGrafik

SPECIFICATIONS

SERIAL TECHNOLOGY
485HESP
Connectors, line 3-position terminal blocks
Connectors, equipment 3-position terminal blocks
232HESP/422HESP
Connectors, line 5-position terminal blocks
Connectors, equipment 5-position terminal blocks
SURGE SUPPRESSION
Clamping Voltage
- stage 1
72 VDC, minimum
108 VDC, maximum
Series Resistance
- stage 2
2.7 Ohms
Clamping Voltage
- stage 3
Models 422HESP, 485HESP:
6.45 VDC, minimum
7.14 VDC, maximum
Model 232HESP:
14.3 VDC, minimum
15.8 VDC, maximum
Clamping Time Less than 5 x10 9 seconds
Dimensions 11.4 x 8.4 x 4.6 cm (4.5 X 3.3 x 1.8 in)
Installation In-line
Weight 0.19 kg (6.7 oz)
APPROVALS / CERTIFICATIONS - 485HESP
2011/65/EU - Reduction of Hazardous Substance Directive
2012/19/EU - Waste Electrical and Electronic Equipment (WEEE)



ORDERING INFORMATION

MODEL NUMBER INTERFACE LINES PROTECTED MOUNTING
485HESP RS-422/485 (3) RS-422/485 Panel Mount
422HESP RS-422/485 (3) RS-422/485 Panel Mount
232HESP RS-232 (5) RS-232 Panel Mount



Customers who viewed this item also viewed