MOXA EDS-518E Series
14+4G-port Gigabit managed Ethernet switches
- 4 Gigabit plus 14 fast Ethernet ports for copper and fiber
- Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), RSTP/STP, and MSTP for network redundancy
- RADIUS, TACACS+, MAB Authentication, SNMPv3, IEEE 802.1X, MAC ACL, HTTPS, SSH, and sticky MAC-addresses to enhance network security
- Security features based on IEC 62443
- EtherNet/IP, PROFINET, and Modbus TCP protocols supported for device management and monitoring
- Fiber Check??comprehensive fiber status monitoring and warning on MST/MSC/SSC/SFP fiber ports
- Supports MXstudio for easy, visualized industrial network management
- V-ON™ ensures millisecond-level multicast data and video network recovery
The EDS-518E standalone, compact 18-port managed Ethernet switches have 4 combo Gigabit ports with built-in RJ45 or SFP slots for Gigabit fiber-optic communication. The 14 fast Ethernet ports have a variety of copper and fiber port combinations that give the EDS-518E Series greater flexibility for designing your network and application. The Ethernet redundancy technologies Turbo Ring, Turbo Chain, RSTP/STP, and MSTP increase the system reliability and availability of your network backbone. The EDS-518E also supports advanced management and security features.
In addition, the EDS-518E Series is designed specifically for harsh industrial environments with limited installation space and high protection level requirements, such as maritime, rail wayside, oil and gas, factory automation, and process automation.
Additional Features and Benefits
- DHCP Option 82 for IP address assignment with different policies
- Supports EtherNet/IP, PROFINET, and Modbus TCP protocols for device management and monitoring
- IGMP snooping and GMRP for filtering multicast traffic
- Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network planning
- QoS (IEEE 802.1p/1Q and TOS/DiffServ) to increase determinism
- Port Trunking for optimum bandwidth utilization
- Port mirroring for online debugging
- Automatic warning by exception through email and relay output
- SNMPv1/v2c/v3 for different levels of network management
- RMON for proactive and efficient network monitoring
- Fiber Check™ provides a comprehensive fiber Digital Diagnostic Monitoring (DDM) function and event warning on MST/MSC/SSC/SFP fiber ports
- Bandwidth management to prevent unpredictable network status
- Lock port function for blocking unauthorized access based on MAC address
- Supports the ABC-02-USB (Automatic Backup Configurator) for system configuration backup/restore and firmware upgrade
Specifications
- Input/Output Interface
- Alarm Contact Channels
1
Relay output with current carrying capacity of 1 A @ 24 VDC
Buttons
Reset button
Digital Input Channels
1
Digital Inputs
+13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
Ethernet Interface
- 10/100BaseT(X) Ports (RJ45 connector)
EDS-518E-4GTXSFP: 14
EDS-518E-MM-SC-4GTXSFP/MM-ST-4GTXSFP/SS-SC-4GTXSFP: 12 All models support:
Auto negotiation speed
Full/Half duplex mode
Auto MDI/MDI-X connection
Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP+)
4
10/100/1000BaseT(X) Ports (RJ45 connector)
Auto negotiation speed
Full/Half duplex mode
Auto MDI/MDI-X connection
100BaseFX Ports (multi-mode SC connector)
EDS-518E-MM-SC-4GTXSFP Series: 2
100BaseFX Ports (multi-mode ST connector)
EDS-518E-MM-ST-4GTXSFP Series: 2
100BaseFX Ports (single-mode SC connector)
EDS-518E-SS-SC-4GTXSFP Series: 2
Optical Fiber
100BaseFX | ||||
---|---|---|---|---|
Multi-Mode | Single-Mode | |||
Fiber Cable Type | OM1 | 50/125 µm | G.652 | |
800 MHz x km | ||||
Typical Distance | 4 km | 5 km | 40 km | |
Wavelength | Typical (nm) | 1300 | 1310 | |
TX Range (nm) | 1260 to 1360 | 1280 to 1340 | ||
RX Range (nm) | 1100 to 1600 | 1100 to 1600 | ||
Optical Power | TX Range (dBm) | -10 to -20 | 0 to -5 | |
RX Range (dBm) | -3 to -32 | -3 to -34 | ||
Link Budget (dB) | 12 | 29 | ||
Dispersion Penalty (dB) | 3 | 1 |
Note:
When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.
Note:
Compute the "typical distance" of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
IEEE 802.3x for flow control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1X for authentication
IEEE 802.3ad for Port Trunk with LACP
Ethernet Software Features
- Filter
802.1Q VLAN
BPDU Filter
BPDU Guard
GMRP
GVRP
IGMP v1/v2/v3
Port-based VLAN
Industrial Protocols
EtherNet/IP
Modbus TCP
PROFINET IO Device
Management
LLDP
Back Pressure Flow Control
BOOTP
Port Mirror
DHCP Option 66/67/82
DHCP Server/Client
Fiber check
Flow control
IPv4/IPv6
RARP
RMON
SCP
SMTP
SNMP Inform
SNMPv1/v2c/v3
Syslog
Telnet
TFTP
MIB
Ethernet-like MIB
MIB-II
Bridge MIB
P-BRIDGE MIB
Q-BRIDGE MIB
RMON MIB Groups 1, 2, 3, 9
RSTP MIB
Redundancy Protocols
Link Aggregation
MRP
MSTP
RSTP
STP
Turbo Chain
Turbo Ring v1/v2
Security
Broadcast storm protection
HTTPS/SSL
TACACS+
SNMPv3
MAB authentication
Sticky MAC
NTP authentication
MAC ACL
Port Lock
RADIUS
SSH
SMTP with TLS
Time Management
NTP Server/Client
SNTP
Switch Properties
- IGMP Groups
2048
MAC Table Size
16 K
Max. No. of VLANs
64
Packet Buffer Size
1 Mbits
Priority Queues
4
VLAN ID Range
VID 1 to 4094
USB Interface
- Storage Port
USB Type A
LED Interface
- LED Indicators
PWR1, PWR2, STATE, FAULT, 10/100M (TP port), 100M (fiber port), Gigabit combo port, MSTR/HEAD, CPLR/TAIL
Serial Interface
- Console Port
USB-serial console (Type B connector)
DIP Switch Configuration
- DIP Switches
Turbo Ring, Master, Coupler, Reserve
Power Parameters
- Connection
2 removable 4-contact terminal block(s)
Input Current
EDS-518E-4GTXSFP Series: 0.37 A @ 24 VDC
EDS-518E-MM-SC-4GTXSFP/MM-ST-4GTXSFP/SS-SC-4GTXSFP: 0.41 A @ 24 VDC
Input Voltage
12/24/48/-48 VDC
Redundant dual inputs
Operating Voltage
9.6 to 60 VDC
Overload Current Protection
Supported
Reverse Polarity Protection
Supported
Physical Characteristics
- Housing
Metal
IP Rating
IP30
Dimensions
94 x 135 x 137 mm (3.7 x 5.31 x 5.39 in)
Weight
1518 g (3.35 lb)
Installation
DIN-rail mounting
Wall mounting (with optional kit)
Environmental Limits
- Operating Temperature
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
- Safety
UL 508
EN 60950-1 (LVD)
EMC
EN 61000-6-2/-6-4
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
Hazardous Locations
ATEX
Class I Division 2
Maritime
DNV-GL
LR
ABS
NK
Power Substation
IEC 61850-3
IEEE 1613
Railway
EN 50121-4
Traffic Control
NEMA TS2
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
MTBF
- Time
723,953 hrs
Standards
Telcordia (Bellcore), GB
Package Contents
- Device
1 x EDS-518E Series switch
Cable
1 x USB type A male to USB type B male
Installation Kit
4 x cap, plastic, for RJ45 port
4 x cap, plastic, for SFP slot
Documentation 1 x quick installation guide
1 x warranty card
1 x product certificates of quality inspection, Simplified Chinese
1 x product notice, Simplified Chinese
Note
SFP modules need to be purchased separately for use with this product.
Ordering Information
Model Name | 10/100BaseT (X) Ports RJ45 Connector |
Combo Ports 10/100/ 1000BaseT(X) or 100/1000BaseSFP+ |
100BaseFX Ports Multi-Mode, SC Connector |
100BaseFX Ports Multi-Mode, ST Connector |
100BaseFX Ports Single-Mode, SC Connector |
Operating Temp. |
---|---|---|---|---|---|---|
EDS-518E-4GTXSFP | 14 | 4 | - | - | - | -10 to 60°C |
EDS-518E-4GTXSFP-T | 14 | 4 | - | - | - | -40 to 75°C |
EDS-518E-MM-SC-4GTXSFP | 12 | 4 | 2 | - | - | -10 to 60°C |
EDS-518E-MM-SC-4GTXSFP-T | 12 | 4 | 2 | - | - | -40 to 75°C |
EDS-518E-MM-ST-4GTXSFP | 12 | 4 | - | 2 | - | -10 to 60°C |
EDS-518E-MM-ST-4GTXSFP-T | 12 | 4 | - | 2 | - | -40 to 75°C |
EDS-518E-SS-SC-4GTXSFP | 12 | 4 | - | - | 2 | -10 to 60°C |
EDS-518E-SS-SC-4GTXSFP-T | 12 | 4 | - | - | 2 | -40 to 75°C |
Accessories (sold separately)
Storage Kits | |
ABC-02-USB | Configuration backup and restoration tool, firmware upgrade, and log file storage tool for managed Ethernet switches and routers, 0 to 60°C operating temperature |
ABC-02-USB-T | Configuration backup and restoration tool, firmware upgrade, and log file storage tool for managed Ethernet switches and routers, -40 to 75°C operating temperature |
SFP Modules | |
SFP-1FELLC-T | SFP module with 1 100Base single-mode with LC connector for 80 km transmission, -40 to 85°C operating temperature |
SFP-1FEMLC-T | SFP module with 1 100Base multi-mode, LC connector for 2/4 km transmission, -40 to 85°C operating temperature |
SFP-1FESLC-T | SFP module with 1 100Base single-mode with LC connector for 40 km transmission, -40 to 85°C operating temperature |
SFP-1G10ALC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1310 nm, RX 1550 nm, 0 to 60°C operating temperature |
SFP-1G10ALC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1310 nm, RX 1550 nm, -40 to 85°C operating temperature |
SFP-1G10BLC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1550 nm, RX 1310 nm, 0 to 60°C operating temperature |
SFP-1G10BLC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1550 nm, RX 1310 nm, -40 to 85°C operating temperature |
SFP-1G20ALC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1310 nm, RX 1550 nm, 0 to 60°C operating temperature |
SFP-1G20ALC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1310 nm, RX 1550 nm, -40 to 85°C operating temperature |
SFP-1G20BLC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1550 nm, RX 1310 nm, 0 to 60°C operating temperature |
SFP-1G20BLC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1550 nm, RX 1310 nm, -40 to 85°C operating temperature |
SFP-1G40ALC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1310 nm, RX 1550 nm, 0 to 60°C operating temperature |
SFP-1G40ALC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1310 nm, RX 1550 nm, -40 to 85°C operating temperature |
SFP-1G40BLC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1550 nm, RX 1310 nm, 0 to 60°C operating temperature |
SFP-1G40BLC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1550 nm, RX 1310 nm, -40 to 85°C operating temperature |
SFP-1GEZXLC | SFP module with 1 1000BaseEZX port with LC connector for 110 km transmission, 0 to 60°C operating temperature |
SFP-1GEZXLC-120 | SFP module with 1 1000BaseEZX port with LC connector for 120 km transmission, 0 to 60°C operating temperature |
SFP-1GLHLC | SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, 0 to 60°C operating temperature |
SFP-1GLHLC-T | SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, -40 to 85°C operating temperature |
SFP-1GLHXLC | SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C operating temperature |
SFP-1GLHXLC-T | SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, -40 to 85°C operating temperature |
SFP-1GLSXLC | SFP module with 1 1000BaseLSX port with LC connector for 1km/2km transmission, 0 to 60°C operating temperature |
SFP-1GLSXLC-T | SFP module with 1 1000BaseLSX port with LC connector for 1km/2km transmission, -40 to 85°C operating temperature |
SFP-1GLXLC | SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C operating temperature |
SFP-1GLXLC-T | SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C operating temperature |
SFP-1GSXLC | SFP module with 1 1000BaseSX port with LC connector for 300m/550m transmission, 0 to 60°C operating temperature |
SFP-1GSXLC-T | SFP module with 1 1000BaseSX port with LC connector for 300m/550m transmission, -40 to 85°C operating temperature |
SFP-1GZXLC | SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C operating temperature |
SFP-1GZXLC-T | SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C operating temperature |
Wall-Mounting Kits | |
WK-51-01 | Wall mounting kit with 2 plates (51.6 x 67 x 2 mm) and 6 screws |
Software | |
MXview-50 | Industrial network management software with a license for 50 nodes (by IP address) |
MXview-100 | Industrial network management software with a license for 100 nodes (by IP address) |
MXview-250 | Industrial network management software with a license for 250 nodes (by IP address) |
MXview-500 | Industrial network management software with a license for 500 nodes (by IP address) |
MXview-1000 | Industrial network management software with a license for 1000 nodes (by IP address) |
MXview-2000 | Industrial network management software with a license for 2000 nodes (by IP address) |
MXview Upgrade-50 | MXview Upgrade-50 License expansion of MXview industrial network management software by 50 nodes (by IP address) |
Customers who viewed this item also viewed