Logo

MOXA EDS-G509 Series

SPHINX in Europe »  ch es de fr at dk it nl be  «
Phone: +44 (0) 1276 819333 |  Legal Notice |  Contact
     Lupe

You are here » MOXA EDS-G509 Series «

MOXA EDS-G509 Series

prodgraf


9-Port full Gigabit managed Ethernet switches



Properties


Description

The EDS-G509 is equipped with 9 Gigabit Ethernet ports and up to 5 fiber optic ports, making it ideal for upgrading an existing network to Gigabit speed or building a new full Gigabit backbone. Gigabit transmission increases bandwidth for higher performance and transfers large amounts of video, voice, and data across a network quickly. Redundant Ethernet Turbo Ring and RSTP/STP (IEEE 802.1w/D) increase system reliability and the availability of your network backbone.
The EDS-G509 series is designed especially for communication demanding applications, such as video and process monitoring, shipbuilding, ITS, and DCS systems, all of which can benefit from a scalable backbone construction.



ProdGrafik

Further Information


Technology

Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP

Protocols
IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, EtherNet/IP, Modbus/TCP, SNMP Inform, LLDP, IEEE 1588 PTPv2, IPv6, NTP Server/Client

MIB
MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9

Flow Control
IEEE 802.3x flow control, back pressure flow control


Switch Properties

Priority Queues
4

Max. Number of Available VLANs
64

VLAN ID Range
VID 1 to 4094

IGMP Groups
256

MAC Table Size
8 K

Packet Buffer Size
1 Mbit


Interface

Fiber Ports
100/1000BaseSFP slot

RJ45 Ports
10/100/1000BaseT(X) auto negotiation speed

Console Port
RS-232 (RJ45 connector)

DIP Switches
Turbo Ring, Master, Coupler, Reserve

LED Indicators
PWR1, PWR2, FAULT, 10/100/1000M, MSTR/HEAD, CPLR/TAIL

Alarm Contact
2 relay outputs with current carrying capacity of 1 A @ 24 VDC

Digital Inputs
2 inputs with the same ground, but electrically isolated from the electronics.
Power Requirements

Input Voltage
12/24/48 VDC, redundant dual inputs

Input Current
0.81 A @ 24 V

Overload Current Protection
Present

Connection
2 removable 6-contact terminal blocks

Reverse Polarity Protection
Present


Physical Characteristics

Housing
Metal, IP30 protection

Dimensions
87.1 135 107 mm (3.43 5.31 4.21 in)

Weight
1510 g

Installation
DIN-rail mounting, wall mounting (with optional kit)


Environmental Limits

Operating Temperature
Standard Models: 0 to 60C (32 to 140F)
Wide Temp. Models: -40 to 75C (-40 to 167F)

Storage Temperature
-40 to 85C (-40 to 185F)

Ambient Relative Humidity
5 to 95% (non-condensing)


Standards and Certifications

Safety
UL 508, EN 60950-1

EMI
FCC Part 15 Subpart B Class A, EN 55022 Class A

EMS
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3,
EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) Level 3, EN61000-4-8

Marine
DNV, GL, LR, ABS, NK

Rail Traffic
EN 50121-4

Shock
IEC 60068-2-27

Freefall
IEC 60068-2-32

Vibration
IEC 60068-2-6


MTBF (mean time between failures)

Time
598659 hrs

Database
Telcordia (Bellcore), GB



Ordering information:

Managed Ethernet Switches
Model No. Description
EDS-G509 Industrial full Gigabit managed Ethernet switch with 4
10/100/1000BaseT(X) ports, and 5 10/100/1000BaseT(X)
or 1000BaseSFP slot combo ports, 0 to 60C
EDS-G509-T Industrial full Gigabit Ethernet switch with 4 10/100/1000BaseT(X) ports,
and 5 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slot combo ports,
-40 to 75C operating temperature

DIN Rail Power Supplies
Model No. Description
DR-45-24 45W/2A DIN-Rail 24 VDC power supply, 85 to 264 VAC input
DR-75-24 75W/3.2A DIN-Rail 24 VDC power supply, 85 to 264 VAC input
DR-120-24 120W/5A DIN-Rail 24 VDC power supply, 88 to 132 VAC / 176 to 264 VAC input by switch
DR-120-48 120W/2.5A DIN-Rail 48 VDC power supply, 88 to 132 VAC / 176 to 264 VAC input by switch

Accessories - SNMP OPC Server Pro Software
Model No. Description
EDS-SNMP OPC Server Pro CD with EDS-SNMP OPC Server Pro Software and Manual

Backup Configurator
Model No. Description
ABC-01 Automatic Backup Configurator through the RS-232 console port, 0 to 60C

Mounting Kits
Model No. Description
RK-4U 4U-high 19 rack mounting kit
WK-46 Wall mounting kit


SFP-1G Modules
Model No. Description
SFP-1GSXLC for 0.5 km transmission, 0 to 60C
SFP-1GLSXLC SFP module with 1 1000BaseSX port with LC connector
for 2 km transmission, 0 to 60C
SFP-1GLXLC SFP module with 1 1000BaseLX port with LC connector
for 10 km transmission, 0 to 60C
SFP-1GLHXLC SFP module with 1 1000BaseLHX port with LC connector
for 40 km transmission, 0 to 60C
SFP-1GZXLC SFP module with 1 1000BaseZX port with LC connector
for 80 km transmission, 0 to 60C
SFP-1GEZXLC SFP module with 1 1000BaseEZX port with LC connector
for 110 km transmission, 0 to 60C
SFP-1G10ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 10 km transmission,
TX 1310 nm, RX 1550 nm, 0 to 60C
SFP-1G10BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 10 km transmission,
TX 1550 nm, RX 1310 nm, 0 to 60C
SFP-1G20ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 20 km transmission,
TX 1310 nm, RX 1550 nm, 0 to 60C
SFP-1G20BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 20 km transmission,
TX 1550 nm, RX 1310 nm, 0 to 60C
SFP-1G40ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 40 km transmission,
TX 1310 nm, RX 1550 nm, 0 to 60C
SFP-1G40BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 40 km transmission,
TX 1550 nm, RX 1310 nm, 0 to 60C
SFP-1GSXLC-T SFP module with 1 1000BaseSX port with LC connector
for 0.5 km transmission, -20 to 75C
SFP-1GLSXLC-T SFP module with 1 1000BaseSX port with LC connector
for 2 km transmission, -40 to 85C
SFP-1GLXLC-T SFP module with 1 1000BaseLX port with LC connector
for 10 km transmission, -40 to 85C
SFP-1GLHXLC-T SFP module with 1 1000BaseLHX port with LC connector
for 40 km transmission, -40 to 85C
SFP-1GZXLC-T SFP module with 1 1000BaseZX port with LC connector
for 80 km transmission, -40 to 85C
SFP-1G10ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 10 km transmission,
TX 1310 nm, RX 1550 nm, -40 to 85C
SFP-1G10BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 10 km transmission,
TX 1550 nm, RX 1310 nm, -40 to 85C
SFP-1G20ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 20 km transmission,
TX 1310 nm, RX 1550 nm, -40 to 85C
SFP-1G20BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 20 km transmission,
TX 1550 nm, RX 1310 nm, -40 to 85C
SFP-1G40ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 40 km transmission,
TX 1310 nm, RX 1550 nm, -40 to 85C
SFP-1G40BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port
with LC connector for 40 km transmission,
TX 1550 nm, RX 1310 nm, -40 to 85C


SFP-FE Modules
Model No. Description
SFP-1FEMLC-T SFP module with 100Base multi-mode with LC connector
for 4 km transmission, -40 to 85C
SFP-1FESLC-T SFP module with 100Base single-mode with LC connector
for 40 km transmission, -40 to 85C
SFP-1FELLC-T SFP module with 100Base single-mode with LC connector for 80 km transmission, -40 to 85C


Ordering Information SFP Modules
Available Models Port Interface
Standard Temperature
(-40 to 85C)
Wide Temperature
(0 to 60C)
1000BaseSX, LC Connector, 0.5 km 1000BaseLSX, LC Connector, 2 km 1000BaseLX, LC Connector, 10 km 1000BaseLH, LC Connector, 30 km 1000BaseLHX, LC Connector, 40 km 1000BaseZX, LC Connector, 80 km 1000BaseEZX, LC Connector, 100 km
SFP-1GSXLC SFP-1GSXLC-T∗ 1 --- --- --- --- --- ---
SFP-1GLSXLC SFP-1GLSXLC-T --- 1 --- --- --- --- ---
SFP-1GLXLC SFP-1GLXLC-T --- --- 1 --- --- --- ---
SFP-1GLHLC SFP-1GLHLC-T --- --- --- 1 --- --- ---
SFP-1GLHXLC SFP-1GLHXLC-T --- --- --- --- 1 --- ---
SFP-1GZXLC SFP-1GZXLC-T --- --- --- --- --- 1 ---
SFP-1GEZXLC --- --- --- --- --- --- --- 1


∗Note: SFP-1GSXLC-T: -20 to 75C operating temperature

Ordering Information WDM-type (BiDi) SFP Modules
Available Models Port Interface
Standard Temperature
(0 to 60C)
Wide Temperature (-40 to 85C) 1100BaseSFP, LC Connector, 11 km 1100BaseSFP, LC Connector, 20 km 1100BaseSFP, LC Connector, 40 km
TX 1311 nm,
RX 1550 nm
TX 1550 nm,
RX 1311 nm
TX 1311 nm,
RX 1550 nm
TX 1550 nm,
RX 1311 nm
TX 1311 nm,
RX 1550 nm
TX 1550 nm,
RX 1311 nm
SFP-1G11ALC SFP-1G11ALC-T 1 --- --- --- --- ---
SFP-1G11BLC SFP-1G11BLC-T --- 1 --- --- --- ---
SFP-1G20ALC SFP-1G20ALC-T --- --- 1 --- --- ---
SFP-1G20BLC SFP-1G20BLC-T --- --- --- 1 --- ---
SFP-1G40ALC SFP-1G40ALC-T --- --- --- --- 1 ---
SFP-1G40BLC SFP-1G40BLC-T --- --- --- --- --- 1



PDF

PDF description MOXA EDS-G509 Series Datasheet (1111.4 kB)

PDF description MOXA SFP-1G Series Datasheet (759.8 kB)



Copyright © 2013 SPHINX Computer Vertriebs GmbH